Load monitor active

Load monitor controlling electrical addition

Nibe · F1155 Heat Pumps

What does Load monitor active mean?

The heat pump has integrated load monitors to manage the electrical addition's power usage. It redistributes power or disengages the addition if the property's main fuse risks tripping due to overload.

Common Causes

  • High power consumption from other appliances
  • Electrical addition is operating
  • Property's main fuse is close to its limit

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check if the property's main fuse is set correctly in menu 5.1.12.

  2. 2

    Ensure current sensors are correctly installed on each incoming phase conductor and connected to AA3:X4.

  3. 3

    The system will automatically redistribute power or disengage the electrical addition during overload.

  4. 4

    Reconnection occurs when other power consumption is reduced.