Cooling high pressure control activated — RUN LED flashes 3 times, TIMER LED flashes 5 times

Mitsubishi Heavy Industries · Air Conditioners

What does 35 mean?

The system's high-pressure control has activated during cooling operation and caused the compressor to stop. This indicates issues with refrigerant levels, closed service valves, or inefficient heat exchange.

Common Causes

  • Service valve is closed or partially obstructed
  • Refrigerant is insufficient or overcharged
  • Compressor lock or overload operation
  • Faulty outdoor heat exchanger sensor

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Ensure all service valves on the outdoor unit are fully open.

  2. 2

    Check the refrigerant level; it may be insufficient or overcharged, requiring adjustment by a technician.

  3. 3

    Verify the outdoor unit has good ventilation and is not experiencing overload operation due to environmental factors or blockages.

  4. 4

    If the issue persists, the compressor may be locked or faulty, or the outdoor heat exchanger sensor could be malfunctioning.