8D

8D — Outdoor liquid pipe temperature thermistor (TH3) open/short

Mitsubishi Electric · MXZ Air Conditioners

What does 8D mean?

This error indicates a fault with thermistor TH3, which measures the outdoor liquid pipe temperature. This suggests an open or short circuit in the sensor or its wiring.

Common Causes

  • Damaged outdoor liquid pipe thermistor (TH3).
  • Loose or corroded thermistor connection.
  • Faulty wiring leading to the thermistor.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Turn off the main power to the outdoor unit by switching off its dedicated circuit breaker.

  2. 2

    Locate thermistor TH3 on the outdoor liquid pipe and inspect its wiring connections for any damage or looseness.

  3. 3

    Ensure the thermistor probe is securely fastened to the pipe.

  4. 4

    Power cycle the unit by turning the breaker back on after inspection.

  5. 5

    This requires a technician to test the thermistor's resistance and replace it if found faulty.