OPERATION INDICATOR 2 blinks

OPERATION INDICATOR lamp blinks 2 times — Indoor coil or room temperature thermistor error

Mitsubishi Electric · MSZ-AY Air Conditioners

What does OPERATION INDICATOR 2 blinks mean?

The indoor unit's upper lamp blinks twice, indicating an issue with either the indoor coil thermistor or the room temperature thermistor. The thermistor might be short-circuited or have an open circuit.

Common Causes

  • Indoor coil thermistor is short-circuited
  • Indoor coil thermistor has an open circuit
  • Room temperature thermistor is short-circuited
  • Room temperature thermistor has an open circuit

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Refer to the characteristics of the indoor coil thermistor and room temperature thermistor (10-7) in the full manual.

  2. 2

    Turn OFF the power supply to the unit at the circuit breaker, then turn it back ON after 30 seconds to reset.

  3. 3

    If the issue persists, a qualified technician should inspect the thermistors and their connections.

Browse all codes in this manual (43)
Verified technical data. Last updated: April 2026

Related Faults

AIR PURIFYING lamp 2 blinksAIR PURIFYING lamp blinks 2 times — Front panel not firmly closed or interlock switch issueAIR PURIFYING lamp 2-time blinkAIR PURIFYING lamp blinks 2 times — Air Purifying device error (real-time)AIR PURIFYING lamp continuous blinkAIR PURIFYING lamp continuously blinks — Air purifying device dirty, wet, or malfunction