The left lamp of the OPERATION INDICATOR blinks five times, followed by a 2.5-second pause. This means the compressor stopped three consecutive times within one minute after startup due to overcurrent protection or startup failure protection.
Click steps to track your progress.
Turn OFF the power supply to the unit.
Refer to 'How to check of inverter/compressor' (in the outdoor unit service manual).
Check the stop valve of the outdoor unit.