Fuse (F11) blown only

Fuse (F11) blown only — Potential indoor fan motor or control board issue

Mitsubishi Electric · Air Conditioning

What does Fuse (F11) blown only mean?

Only the fuse (F11) on the indoor power P.C. board has blown. This could indicate a problem with the indoor fan motor or the electronic control P.C. board.

Common Causes

  • Indoor fan motor fault
  • Indoor electronic control P.C. board fault
  • Short circuit in connected components

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Turn off the power supply and replace the fuse (F11).

  2. 2

    Measure the resistance of the indoor fan motor connector (CN211). If resistance is low (short circuit), replace the fan motor.

  3. 3

    Measure the resistance of resistor (R111) or reactor (L111) on the indoor power P.C. board. If readings are abnormal, consider replacing the board.

  4. 4

    If the fuse blows again immediately, further diagnosis of the fan motor and control board is needed.