Electricity not conducted between CN201 and S2

No continuity between CN201 and S2 — Terminal block assembly fault

Mitsubishi Electric · Air Conditioning

What does Electricity not conducted between CN201 and S2 mean?

There is no electrical conduction (0 Ω resistance) between the connector CN201 on the indoor power P.C. board and S2 on the terminal block. This indicates a break in the wiring path.

Common Causes

  • Faulty terminal block assembly
  • Internal wiring break between CN201 and S2
  • Poor connection at the terminal block

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Turn off the power supply.

  2. 2

    Check the continuity between CN201 and S2 using a tester.

  3. 3

    Replace the terminal block assembly if continuity is not established.

  4. 4

    Inspect the wiring harness connected to the terminal block.