F1

Outdoor Board LED green (once) and red (once) blink alternately after startup - Incorrect connection of outdoor terminal block

MHI · Air Conditioning

What does F1 mean?

After the initial 'startup' sequence, if the outdoor unit's LED1 (green) blinks once and LED2 (red) blinks once alternately, it indicates an incorrect connection of the outdoor terminal block (L1, L2, S1, S2, S3).

Common Causes

  • Incorrect connection of outdoor terminal block (L1, L2, S1, S2, S3).

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Turn off the main power supply to the unit.

  2. 2

    Carefully check the connections of the outdoor terminal block (L1, L2, S1, S2, S3) and ensure they are correct.

  3. 3

    Restore power and re-check the display.

Browse all codes in this manual (124)
Verified technical data. Last updated: April 2026

Related Faults

00Outdoor Board LED only green lights up after startup - No outdoor unit of address 0 / Remote controller transmission wire open1OPERATION INDICATOR lamp blinks 1 time (Pattern A) - Indoor/outdoor unit communication error (Transmitting error - Outdoor unit)14OPERATION INDICATOR lamp blinks 14 times (Pattern A) - Other errors