FA

FA — Ionization current remains after controlled shutdown

Junkers · CERASTAR CERAMINI Boiler

What does FA mean?

The boiler detects an ionization current (indicating a flame) even after it has attempted a controlled shutdown. This is a safety critical issue as gas may still be burning or leaking.

Common Causes

  • Incorrect ionization signal from the electrode.
  • The ionization electrode or its connection cable is damaged or faulty.
  • A gas valve issue, potentially allowing gas to pass even when closed.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the ionization electrode and its connection cable for any damage, disconnections, or incorrect positioning.

  2. 2

    Ensure the gas valve is closing completely and correctly after the burner shuts down.

  3. 3

    Due to safety concerns, this issue requires inspection by a qualified gas technician to check the gas valve and other components.