EA

EA — No ionization current

Junkers · CERASTAR CERAMINI Boiler

What does EA mean?

The boiler is not detecting any ionization current, which means there is no flame present or the flame detection system is not working. This will prevent the boiler from igniting or operating.

Common Causes

  • The gas tap is closed or there is an interruption in the gas supply.
  • Insufficient gas connection pressure to light the burner.
  • The ignition electrode with its cable is faulty or incorrectly positioned.
  • The ionization electrode with its cable is faulty or incorrectly positioned.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check that the main gas tap to the boiler is fully open and that there is gas supply to your property.

  2. 2

    Verify the gas connection pressure; it must be within the specified range for the boiler to operate.

  3. 3

    Inspect the ignition electrode and its cable for any damage, dirt, or incorrect spacing/positioning.

  4. 4

    Inspect the ionization electrode and its cable for any damage, dirt, or incorrect spacing/positioning. These usually require professional adjustment.