husqvarna · Automower 310/315/315x
The mower displays a message indicating that it cannot detect the boundary loop signal. This can be due to power issues with the charging station, a problem with the boundary wire itself, or signal interference.
Click steps to track your progress.
Check that the charging station's LED indicator is lit. If not, verify the power supply is connected to a working wall socket and the low-voltage cable is securely attached to the charging station.
Inspect the boundary wire connectors at the charging station to ensure they are properly fitted and not damaged.
Check the charging station's LED indicator for a blue flashing light, which signals a break in the boundary wire. If so, locate and repair the break (see page 49, 52-53).
If ECO mode is active, ensure the mower starts from within the charging station by placing it inside, pressing START, and closing the hatch.
If islands are used, confirm the boundary wire is laid correctly around them (page 18).
Place the mower in the charging station and generate a new loop signal through the mower's menu (page 25).