F3 (4 flashes)

F3 (4 flashes) — Communication fault between Power module and outdoor PCB

Haier · Air Conditioning

What does F3 (4 flashes) mean?

This error indicates a communication failure specifically between the Power Module and the main outdoor Printed Circuit Board (PCB).

Common Causes

  • Outdoor PCB is broken
  • IPM module is broken
  • Communication wiring is disconnected

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Turn off the power switch before checking connections.

  2. 2

    Verify that the terminals CN23/CN24 (Outdoor PCB) and CN10/CN11 (IPM module) are tightly connected.

  3. 3

    Check that the connection between the power module and the power lines (P/N) is secure.

  4. 4

    Turn the power back on and check if the error is resolved.