12

Error Code 12 — Outdoor ambient temperature sensor fault

Haier · Air Conditioning

What does 12 mean?

There is an electrical failure with the sensor that measures the outdoor air temperature. This sensor is connected to the PCB.

Common Causes

  • Defective ambient temperature sensor
  • Loose or damaged sensor wiring
  • Open or shorted sensor circuit

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check that the sensor wiring is firmly and correctly connected to Plug CN-14 on the PCB.

  2. 2

    Inspect the sensor wiring for any damage.

  3. 3

    Test the sensor's resistance against the values in the manual's reference section.

  4. 4

    Replace the sensor if it is found to be faulty.

Browse all codes in this manual (103)