68

Error 68 (6 Green, 8 Red Flashes) — Outdoor unit magnetic relay error

Fujitsu · Air to Water Heat Pumps

What does 68 mean?

The hydraulic unit's green LED flashes six times and the red LED flashes eight times. This indicates a problem with a magnetic relay within the outdoor unit, which controls various electrical circuits.

Common Causes

  • Failure of the magnetic relay itself.
  • Loose or corroded wiring connected to the relay.
  • Control circuit malfunction preventing proper relay operation.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Turn off the heat pump system at the main breaker for at least one minute, then restore power.

  2. 2

    Listen for any unusual clicking sounds from the outdoor unit that might indicate a struggling relay.

  3. 3

    Ensure that the power supply to the outdoor unit is stable and consistent.

  4. 4

    If the error persists, contact a qualified technician, as a faulty magnetic relay typically requires professional replacement.