Input current-limit setting

Input current-limit setting — Loads must be on AC-out for limiter to work

SolarEdge · ESS Systems

¿Qué significa Input current-limit setting ?

The Input current-limit setting in VEConfigure functions as a threshold for AC current at the AC-in of the Multi/Quattro. For this limiter to be effective, all loads should be installed on the AC-out of the unit.

Causas comunes

  • Loads connected in parallel with the Multi/Quattro bypass the current limiter.
  • The current limiter is intended for AC-in current, not total system load.
  • ESS installation disables PowerAssist and Dynamic current limiter.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Install all intended loads on the AC-out terminals of the Multi or Quattro.

  2. 2

    Ensure the AC Input Current limiter setting accurately reflects the desired maximum current.

  3. 3

    Understand that this setting applies to current in both directions.

  4. 4

    Note that PowerAssist and Dynamic current limiter settings are ignored when ESS is installed.

Ver todos los códigos en este manual (12)
Datos técnicos verificados. Última actualización: April 2026

Fallas relacionadas

Battery discharging then charged every nightBattery discharging then charged every night — Potential Sustain protection or SOC settingESS Relay test PendingESS Relay test Pending — Feed-in disabled until test completesLoads powered by grid, not battery or solarLoads powered by grid, not battery or solar — Check battery SOC, limits, and relay test