4

Battery Over Temperature Shutdown — The battery is too hot

Schneider Electric · MPPT 80

¿Qué significa 4 ?

The battery temperature is too high, causing the system to shut down to prevent damage. Charging will resume once the battery has cooled down sufficiently.

Causas comunes

  • The battery is too hot.
  • High ambient temperature.
  • Overcharging conditions.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Ensure the battery is located in a cool, well-ventilated area.

  2. 2

    Check charging settings to ensure they are appropriate for the battery type and conditions.

  3. 3

    Allow the battery temperature to decrease.

  4. 4

    Verify the battery temperature sensor is correctly installed and functioning.

  5. 5

    Charging will resume automatically when the temperature is within range.

Ver todos los códigos en este manual (34)
Datos técnicos verificados. Última actualización: April 2026

Fallas relacionadas

10Output Under-voltage Immediate — The DC Output Voltage is too low11Output Under-voltage — The DC Output Voltage is too low2Capacitor Over Temperature — The Capacitors are too hot