Low room temperature

Low room temperature — Check heating settings and room thermostats

Nibe · SHB 20

¿Qué significa Low room temperature ?

If the room temperature is consistently low, it may be due to incorrect heating control settings, thermostats being turned down, or issues with the heating curve.

Causas comunes

  • Closed thermostats in several rooms
  • Control module in incorrect operating mode
  • Low set value on automatic heating control
  • Heating curve requires adjustment

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Set thermostats to the maximum in as many rooms as possible.

  2. 2

    Adjust the room temperature via menu 1.1 ('temperature') instead of relying solely on thermostats.

  3. 3

    Check the operating mode in menu 4.2. If set to 'auto', select a higher value for 'stop heating' in menu 4.9.2. If set to 'manual', select 'heating' or 'addition'.

  4. 4

    Adjust the offset heating curve upwards in menu 1.1 ('temperature').

  5. 5

    If the room temperature is only low in cold weather, adjust the heating curve slope upwards in menu 1.9.1.

Ver todos los códigos en este manual (15)