Outdoor Board LED1 (green) blinks three times and LED2 (red) blinks two times alternately - Abnormality of shell thermostat and discharging temperature (TH4)

MHI · Air Conditioning

¿Qué significa U2 ?

During startup or operation, the outdoor unit's LED1 (green) blinks three times and LED2 (red) blinks two times alternately, indicating an abnormality of the shell thermostat and/or discharge temperature sensor (TH4).

Causas comunes

  • Abnormality of shell thermostat and discharging temperature (TH4).
  • Connectors (TH4, LEV-A, and LEV-B) on outdoor controller board are disconnected.
  • Insufficient refrigerant in the unit.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check if connectors (TH4, LEV-A, and LEV-B) on the outdoor controller board are not disconnected.

  2. 2

    Measure resistance values among terminals on indoor valve and outdoor linear expansion valve using a tester.

  3. 3

    Check if the unit is filled with the specified amount of refrigerant.

  4. 4

    Ensure the shell thermostat is properly seated and functioning.

Ver todos los códigos en este manual (124)
Datos técnicos verificados. Última actualización: April 2026

Fallas relacionadas

00Outdoor Board LED only green lights up after startup - No outdoor unit of address 0 / Remote controller transmission wire open1OPERATION INDICATOR lamp blinks 1 time (Pattern A) - Indoor/outdoor unit communication error (Transmitting error - Outdoor unit)14OPERATION INDICATOR lamp blinks 14 times (Pattern A) - Other errors