349

Alert 349 — IFC Error Check

Lennox · Communicating Systems

¿Qué significa 349 ?

This code appears in non-communicating mode and indicates the jumper between O and R on the furnace has been removed, potentially causing low voltage or a brownout condition.

Causas comunes

  • The O to R link on the furnace has been cut.
  • Low voltage condition.
  • Incorrect jumper configuration.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Restore the R to O link by hard-wiring the R to O terminals on the terminal strip.

  2. 2

    Check for correct jumper configuration.

  3. 3

    Ensure proper voltage levels are being supplied to the system.