PA

PA - AC Current Protection

GE Appliances · Air Conditioning

¿Qué significa PA ?

The input AC current has exceeded the set protection value, causing the system to shut down. This can be due to system load, grid voltage issues, or drive board problems. This code is shown on the ODU main board LED.

Causas comunes

  • System is heavy-loaded and compressor current is too large
  • Grid voltage is abnormal
  • PFC module is damaged
  • Drive board PFC current sampling circuit element is damaged

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check if the compressor is running at high frequency and high load; reduce load if possible.

  2. 2

    Verify if the grid voltage is normal.

  3. 3

    Replace the drive board if the PFC module or PFC current sampling circuits are damaged.