Schneider Electric · EVlink Smart Wallbox Charging Stations Troubleshooting
When the door and trap are opened during a specific reset procedure, the indicator lights turn red, signaling entry into troubleshooting mode.
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
Open the door, then open the trap.
Open the contact; the indicator lights will turn red.
Press the right-hand stop button for about 10 seconds until the right-hand red indicator light goes out and the right-hand green indicator light blinks.
Release the button.
Quickly press the green push-button during the subsequent 10 green light blinks to launch the return to factory settings.