Low hot water temperature or lack of hot water

Low hot water temperature or no hot water — Potential causes identified

Nibe · SMO 20 Control Module

Was bedeutet Low hot water temperature or lack of hot water ?

If you experience insufficient hot water, several factors could be the cause, ranging from simple valve settings to operational modes.

Häufige Ursachen

  • External filling valve for hot water is closed
  • Mixing valve set too low
  • Incorrect operating mode selected in SMO 20
  • High hot water consumption
  • Hot water temperature setting too low
  • Low hot water production with 'Smart Control' active
  • Insufficient prioritization of hot water in system settings

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Ensure any externally mounted filling valve for hot water is open.

  2. 2

    Check and adjust the mixing valve setting if one is installed.

  3. 3

    Verify the SMO 20 operating mode in menu 4.2 and adjust 'stop additional heat' in menu 4.9.2 if in 'auto' mode, or select 'addition' if in 'manual' mode.

  4. 4

    If consumption is high, wait for reheating or activate temporary increased hot water capacity in menu 2.1.

  5. 5

    Increase the comfort mode setting in menu 2.2.

  6. 6

    Adjust the hot water prioritization time in menu 4.9.1 if 'Smart Control' is active and usage has been low.