Was bedeutet Low hot water temperature or no hot water ?

This issue can occur if the hot water system settings are incorrect, or if there are problems with the water supply or heating components.

Häufige Ursachen

  • Filling valve for hot water is closed
  • Mixing valve set too low
  • Control module in incorrect operating mode
  • High hot water consumption
  • Low hot water setting
  • Low or no operating prioritisation for hot water

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Ensure the filling valve for the hot water is open.

  2. 2

    Adjust the mixing valve if one is installed, ensuring it is not set too low.

  3. 3

    Check the operating mode in menu 4.2 and select 'addition' if it's set to 'manual'.

  4. 4

    Wait for the hot water to heat up if there has been large consumption; consider activating temporary increased hot water capacity in menu 2.1.

  5. 5

    Increase the hot water comfort setting in menu 2.2.

  6. 6

    Increase the time for hot water prioritisation in menu 4.9.1.