Daikin FTXF-D

32 fault codes documented

4-way valve abnormality

4-way valve abnormality

The 4-way valve, which controls refrigerant flow direction, is malfunctioning.

Beep

Single beep - Setting changes

A single beep indicates that a setting has been successfully changed or accepted by the unit.

Beep-beep

Two beeps - Operation starts

You will hear two short beeps when the indoor unit receives a signal and starts operating.

Blk flashing/Error code displayed

Operation lamp flashes and malfunction code appears

The operation lamp is flashing and a specific malfunction code is shown on the user interface display. This indicates the unit has detected a problem.

Compressor internal temperature error

Compressor internal temperature error

The internal temperature of the compressor has exceeded its safe limit.

Compressor lock

Compressor lock error

The compressor has encountered a lock condition and cannot operate.

Compressor system sensor abnormality

Compressor system sensor abnormality

One of the sensors monitoring the compressor system has a fault.

DC fan lock

Outdoor fan motor lock error

The DC fan motor in the outdoor unit is locked or not rotating.

DC voltage / current sensor abnormality

DC voltage or current sensor abnormality

A sensor measuring DC voltage or current within the unit has a fault.

Discharge pipe temperature control

Discharge pipe temperature control activated

The system has activated protection due to the discharge pipe temperature being too high or too low.

Discharge pipe thermistor abnormality

Discharge pipe thermistor abnormality

The sensor measuring the temperature of the discharge pipe has a fault.

Electrical parts heat error

Electrical parts overheating error

Internal electrical components have overheated, triggering a protective shutdown.

Fan motor (DC motor) abnormality

Indoor fan motor abnormality

The DC fan motor in the indoor unit is not functioning correctly.

Freeze-up protection or high-pressure control

Freeze-up protection or high-pressure control activated

The unit has activated its protection against freezing or excessively high pressure. This often occurs in heating or cooling modes.

High-pressure control (in cooling mode)

High-pressure control activated in cooling mode

The system has detected high pressure during cooling operation and has shut down to protect itself.

Indoor heat exchanger thermistor abnormality

Indoor heat exchanger thermistor abnormality

The sensor measuring the temperature of the indoor heat exchanger has a fault.

Indoor unit PCB abnormality

Indoor unit PCB abnormality

There is a fault with the main control board (PCB) in the indoor unit.

Indoor/outdoor unit combination fault

Indoor and outdoor unit combination fault

The indoor and outdoor units are not compatible or have a configuration error.

Input power overcurrent

Input power overcurrent detected

The unit is drawing too much current from the power supply, indicating a potential electrical issue.

Inverter instantaneous overcurrent (DC)

Inverter instantaneous DC overcurrent

The inverter has detected a very high, sudden current, which can indicate a serious electrical fault.

Long beep

Long beep - Operation stops

A long beep is heard when the unit receives a signal to stop the operation.

Outdoor heat exchanger thermistor abnormality

Outdoor heat exchanger thermistor abnormality

The sensor measuring the temperature of the outdoor heat exchanger has a fault.

Outdoor temperature thermistor abnormality

Outdoor temperature thermistor abnormality

The sensor measuring the outdoor temperature has a fault.

Outdoor unit PCB abnormality

Outdoor unit PCB abnormality

There is a fault with the main control board (PCB) in the outdoor unit.

Overload activation (compressor overload)

Compressor overload protection activated

The compressor has been overloaded and has temporarily shut down to prevent damage.

Overvoltage detection

Overvoltage detected

The system has detected a voltage that is too high. This could damage the unit.

Position sensor abnormality

Position sensor abnormality

A sensor responsible for detecting the position of a component has a fault.

Radiation fin temperature rise

Radiation fin temperature rising too high

The temperature of the radiation fins has risen to a critical level, indicating a potential cooling issue.

Radiation fin thermistor abnormality

Radiation fin thermistor abnormality

The sensor monitoring the temperature of the radiation fins has a fault.

Refrigerant shortage

Refrigerant shortage detected

The system indicates a potential shortage of refrigerant. This can affect cooling and heating performance.

Room temperature thermistor abnormality

Room temperature thermistor abnormality

The sensor that measures the room temperature is not working correctly.

Signal transmission error (between indoor and outdoor unit)

Signal transmission error between indoor and outdoor unit

There is a communication problem between the indoor and outdoor units. This prevents the system from operating correctly.