31

Code 31 — High Pressure Switch Open

Carrier · Residential HVAC Systems

What does 31 mean?

This fault indicates that the high-pressure safety switch has opened, signifying excessively high refrigerant pressure within the system. This causes a shutdown to prevent damage to the compressor.

Common Causes

  • Blocked condenser coil (outdoor unit)
  • Dirty air filter (indoor unit)
  • Overcharged refrigerant system
  • Malfunctioning outdoor fan
  • Closed or blocked air vents

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check and clean your air filters in the indoor unit.

  2. 2

    Ensure the outdoor unit's coil is clean and free of debris, and the fan is spinning freely.

  3. 3

    Verify that all supply and return air vents inside your home are open and unobstructed.

  4. 4

    Turn off the HVAC system at the thermostat and then at the circuit breaker for 30 seconds, then restore power.

  5. 5

    If the fault recurs, contact a qualified HVAC technician, as this involves refrigerant pressure and compressor health.