Red LED 9 flashes

Red LED flashes nine times — Module low voltage

Carrier · 38AP Air Handler

What does Red LED 9 flashes mean?

The voltage supplied to the control module (on T2-T1 terminals) is below 18 VAC for more than 5 seconds. This will stop the compressor. The system will attempt to reset after 5 minutes if the voltage is between 18 and 30 VAC. This alert does not cause a lockout.

Common Causes

  • Low voltage supplied to the control module
  • Incorrect module voltage rating
  • Wiring error in the control circuit

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify that the correct 24 VAC module is installed.

  2. 2

    Check the control circuit wiring for errors.

  3. 3

    Ensure the T2-T1 voltage is within the acceptable range (18-30 VAC).

  4. 4

    Allow 5 minutes for automatic reset if voltage is corrected.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026