4Y

4Y (223) - Flow temperature sensor (CH-NTC) faulty

Buderus · Logamax Plus GB062 Boiler

What does 4Y mean?

This error indicates a problem with the central heating flow temperature sensor (CH-NTC). This sensor is vital for measuring the temperature of water flowing out to your heating system.

Common Causes

  • Flow temperature sensor (CH-NTC) is faulty (break or short circuit)
  • Corroded or loose electrical connections to the sensor
  • Damaged wiring leading to the sensor
  • Defective electronic board (PCB)

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Switch off the boiler. Locate the central heating flow temperature sensor and inspect its connections. Remove the socket and visually check for corrosion or damage.

  2. 2

    If you have a multimeter and know the expected resistance values (see NTC tables in a full manual), measure the sensor's resistance. If it's outside the normal range, the sensor may need replacement.

  3. 3

    Check the wiring that connects the flow temperature sensor to the main board for any signs of damage, cuts, or short circuits. Repair or replace as necessary.

  4. 4

    If the issue persists, and you've confirmed the sensor and wiring are okay, the electronic board (PCB) might be at fault and should be checked by a qualified technician.

Browse all codes in this manual (15)