What does OUTDOOR_UNIT_NOT_FOUND mean?

The Evolution Control cannot detect the two-stage communicating outdoor unit. This communication failure stops the outdoor unit from operating.

Common Causes

  • Incorrect or loose ABCD wiring to the outdoor unit
  • Damaged communication wire
  • Outdoor unit control board issue
  • Power supply issue to the outdoor unit

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Recheck all ABCD wiring connections at the outdoor unit's connector.

  2. 2

    Ensure all wire colors are correctly matched at each terminal.

  3. 3

    Verify that 24VAC power is present between the C and D terminals at the outdoor unit.

  4. 4

    Contact an HVAC technician if the unit is not found after checking wiring and power.