CodeRegistry
Brands
  1. Home
  2. Bosch
  3. Heat Pumps
  4. 5513
About·Privacy·Terms

CodeRegistry — Your global library for technical solutions.

For your safety: always follow the equipment manufacturer’s official manuals. CodeRegistry is an independent help site and is not affiliated with the brands listed here.

5513

5513 - Bosch Heat Pump Z1 condensation too high alarm

Bosch · Heat Pumps

What does 5513 mean?

This alarm indicates that condensation levels in Bosch Heat Pump zone 1 are too high. It triggers after 3 warnings in 3 hours, or if a warning is active for 30 minutes.

Common Causes

  • The screw terminal on the I/O board to the drip pan sensor TA4 is not tightened.
  • The drip pan sensor TA4 has failed.
  • A blockage or issue with the Heat Pump's condensation drainage.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check for any visible blockages or overflowing in the Heat Pump's condensation drip pan.

  2. 2

    If the Heat Pump was recently serviced, contact your installer to check the screw terminal on the I/O board for drip pan sensor TA4.

  3. 3

    If the alarm persists, contact a qualified technician to inspect sensor TA4 and the I/O board.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026

Related Faults

5203Alarm Outdoor sensor TL1 faulty5206Alarm Flow sensor T0 faulty5209Alarm Z1 heat transfer fluid out sensor TC1 faulty
Source: Bosch Heat Pumps
Open Manual (Page 11)Search more codes in this manual