E133

E133 — Gas supply fault or ignition failure

Baxi · DUO TEC Boilers

What does E133 mean?

The boiler has failed to ignite, indicating a problem with the gas supply or the ignition system. This includes cases where the condensate trap is frozen or blocked.

Common Causes

  • No gas supply or interrupted gas supply.
  • Faulty spark electrode or sensing electrode, or their cables.
  • Flue gas recirculation.
  • Blocked or frozen condensate trap.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Press the 'Reset' button on the boiler for 1-3 seconds.

  2. 2

    Ensure the main gas supply valve to your property is fully open and other gas appliances are working.

  3. 3

    Check the condensate drain pipe outside for blockages or freezing, especially in cold weather.

  4. 4

    If the error persists, a qualified technician should inspect the ignition system, gas supply pressure, and condensate trap.