E118

E118 — Water pressure too low

Baxi · DUO TEC Boilers

What does E118 mean?

The boiler has detected that the primary heating circuit water pressure is too low, less than 0.5 bar.

Common Causes

  • Insufficient water in the heating system.
  • A leak in the heating system.
  • Faulty pressure sensor.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the system water pressure on the boiler's gauge.

  2. 2

    Re-pressurize the boiler system using the filling loop until the pressure is within the recommended range (typically 1-1.5 bar).

  3. 3

    Check for any visible water leaks from radiators, pipes, or the boiler itself.

  4. 4

    If the problem persists after refilling, a qualified technician should inspect the system for leaks or a faulty pressure sensor.